Depend OnLogic19 February 20265.3 MIN READ

Operating Temperature: Can Your System Take the Heat?

Can your computer handle hot operating temperatures?

A system’s operating temperature range looks simple, but might be better described as a 3D game of chess. The components (their operating temperatures and thermal limits), the ambient temperature in the environment, and the system utilization, all factor into a system rating. This rating is the key to knowing if your computer can take the heat common in industrial & manufacturing environments. A PC rated for 30°C in a 40°C environment can spell disaster which could include: unintended shutdown, data loss, WiFi failure and more. So how do you insulate yourself from failures due to heat? Read on.

Want to learn more about how to choose the best industrial computer?  Download Our Ultimate Checklist for Choosing Industrial Computer Hardware. 

Get the Checklist

Temperature rating: It’s about the parts . . . sort of

Each major component in a PC has its own operating temperature. So to get a system capable of withstanding 60°C heat, you need only select systems with parts with specs above 60°C, right? Not exactly.

Operating temperature represents the operating limits of the part and physical temperature at which the component will fail. Each component will have a range, like the Innodisk wide temperature memory’s -40°C to 85°C. But components such as RAM, storage, WiFi, and processor don’t run in isolation, and they all generate heat. They warm the air around them, and pretty soon a room that is 30°C has parts operating in a 60°C environment. Anyone who has put their hand on the side of a PC case will tell you that they can get pretty warm.

The case makes the difference

Given that components work in an enclosed area, the most important item when it comes to helping determine the rating is the case. The design of a case determines the amount of air flow, the proximity of mounted components, the deployment of heat distribution systems — like heat pipes, heat sinks or fans, and much more. As the components begin to heat up, the case can be the differentiator. A good case will pull heat away from the components. A bad one is an oven in its own right.

Additionally, there are multiple aspects to a thermal rating - primarily you’ll see people concerned with performance and safety. While a system may be able to sustain a workload at a particular ambient temperature, it may also be that an external surface gets hot enough to injure someone.

Both aspects of chassis heat dissipation are important, and it's always a balancing act. In some cases clock speeds or performance may need to be left on the table, while in other instances significant design or material choices might need to be examined and changed.

System operating temperature determination: Part 1:

To get an estimated idea of system thermals and operating temperature ranges, and to aid in design, the first step towards assessing a system is simulation. CAD models of the electronics and chassis are integrated together as they will be when they’re assembled in production, and loaded into a simulation software (we use the cloud-based SimScale). There, they’re parametrically defined - things like heat sources, wattages, materials, air movement, and system orientation/mounting can all be defined. With that information, and direction from a knowledgeable engineer, the simulation platform is able to run Finite Element Analysis (FEA) and Computational Fluid Dynamics (CFD) models to predict system behavior. The outputs of these simulations allow a team to visualize the heat transfer, identify potential issues, and to rapidly test changes and optimizations before even having anything manufactured. 

A diagram showing a thermal simulation test of an OnLogic industrial computer.

Generally, these models and outputs are also revisited once parts have been made and physically tested together as well. It's this feedback loop which allows for continual iterative improvements in the simulations, and increased accuracy over time. This tie back to reality is an essential step in a comprehensive electronics design program and reliable products.

System operating temperature determination: Part 2

Once parts are made and in-hand, to get to the computer's rough operating temperature, first you need a baseline. To establish a baseline, the thermal performance of a PC is assessed at room temperature (~23°C). Every computer manufacturer has a testing process they run machines through. The tests are proprietary and confidential, but all tend to do the same thing: engage the system’s resources to various degrees, while recording the temperatures of the components.

Using this data, the laws of thermodynamics, and some complicated math, they can extrapolate temperatures above and below room temperature and estimate the temperature point where the various components will reach their failure points. This gives the system a preliminary operating temperature, and is often used to quickly assess a configuration.

Case Study

The HX520 Series are fanless ventless computers from OnLogic. During development, we stressed the systems beyond any normal use-case, interested both in system performance as well as system safety. The thermal limits on components being used often are:

  • Processor: 105°C,

  • WiFi: 80°C,

  • Hard drive (an SSD): 80°C

  • Memory: 85°C

Through the substantial internal and laboratory thermal testing, we were able to verify the system for 50°C, which was the highest the ambient temperature could be before one of those parts ticked over its limit. Interestingly at 55°C and even 60°C, some components were still going strong, but reading beyond their rated temperatures, while other components still had margin to go even further.

This is both a good example of good case design, with well placed heat sinks (the HX520 series’ case is one big heat sink), but also a good example of the intricacies of testing. An HX520 Series unit still technically works at 55°C  (5°C above what we rate it for) when heavily stressed with a synthetic workload. If that usage is dialed back to ‘normal’, what do the component operating temperatures look like? It’s hard to say because what is ‘normal’? And for whom? This demonstrates part of why it's so important for customers to also do their own validation.

HX520 Series

System operating temperature determination: Part 3

The next level of thermal testing involves an Environmental Test Chamber. These are basically one part oven, one part freezer. The PC is turned on, set to run a specific workload and is heated up to a specific temperature. Components are monitored with probes and in software as their operating temperatures change. For example, a WiFi card in a room that's 23°C (Room temp) might register as operating at 50°C. When the ambient temperature rises to 40°C, that WiFi will be correspondingly hotter. The process repeats with incrementally higher and higher temperatures, covering the full intended range of system operation

Let’s not forget that systems are also stressed by dropping temperatures too. Using the chamber’s ability to cool to well below freezing, behaviors such as being able to reliably and repeatably boot up at -20°C or even -40°C can be checked. Additionally, things like swings and shifts in temperature can be checked. As temperatures change rapidly, humidity and condensation on and inside electronics needs to be considered. This represents the very worst kinds of (thermal) environments a system may be deployed into.

A K800 computer covered in frost as it is tested in below freezing temperatures

Finally, longer term testing is also considered. Multi-day or even multi-week tests at high system loadings are automated to run and push the system to its limits for prolonged periods. While extreme, this sort of thing is representative of the demands placed on many units, and the sort of reliability expected of industrial computers. HALT (Highly Accelerated Lifecycle Testing) testing can show weaknesses or issues during development that must be resolved before a product releases, and drive product reliability.

And all this means what?

One of the problems with operating temperature, and testing, is the lack of standardization. Some manufacturers use full utilization, which is to say push a computer to its maximum. Optimal utilization is used by others – an ill defined estimate of standard usage levels. Some utilize an Environmental Test Chamber and some do not. The variations go on and on, and are not always meant to be confusing or misleading, they are just all proprietary methods and thus hard to judge against each other. A PC might reach 50°C in one test and 40°C in another, only because the one tester uses software to test the temperature, and the other uses sensors on the components.

With that in mind, a willingness to share data and results through a transparent sales experience counts for a lot. Nothing that anyone is doing is magic - it all boils down to physics, and a trustworthy partner will want you to make an educated choice. Don’t be afraid to ask your vendor how they reached and verified their numbers! 

For the technically inclined, you want to look carefully at the system performance, the case design, the power being consumed by the system, the enclosure (kiosk, cabinet, etc), the software application and its resource draw, and the ambient environment. If you have an application using relatively few system resources, a 50°C rated computer for a factory that never gets hotter than 50°C may be OK. But if there is a big system load or local thermal increases due to an enclosure or poor ventilation, you may need more wiggle room.

Want to learn more about what computer you need for your specific environment? Contact our sales engineering team. We’ll work with you to meet your operating temperature specifications.

Hans Brakely
Hans Brakeley
Hans helps to conceptualize and design products for OnLogic as the Director of Mechanical Engineering. When not at the office, he stays active on a bike or skis, works on cars, and spends time outside playing in the dirt with his dogs.

Stay in the know.

Get first access to the newest products and Industry 4.0 innovation, OnLogic Live! events and more.