Motherboard Information

ASRock Rack X570D4I-2T Motherboard

Specifications

User Manual

Chipset Drivers

Ethernet Drivers

BIOS Hotkey: F2


How to enable auto power on

The auto power on feature will turn the server on automatically when AC power is connected or when power is restored after an outage.

  • Power on the server and press F2 a few times to access the BIOS
  • Navigate to the Advanced tab
  • Open the Chipset Configuration menu
  • Locate the Restore AC Power Loss option
  • Change it to “Power ON’
  • Press F10 to save & exit, and enter to confirm
  • Auto power on is now enabled


How to clear the CMOS

If the server fails to power on or is unresponsive, clearing the CMOS may help. It will also restore the BIOS to factory defaults. Ensure this procedure is done in a static safe environment. A grounding strap is recommended.

  • Unplug the server completely from power and all peripherals
  • Loosen the captive thumbscrew on the back near the power supply
  • Slide the top panel towards the back of the server and lift it off
  • Locate the clear CMOS solder pads
  • Using a flathead screwdriver or similar conductive tool, short the two pins together for 30 seconds
  • Slide the lid back on, reconnect the server, and power it on
  • It may reboot several times to re-detect hardware
  • If it continues to malfunction, contact technical support.

How to dermine the BMC / management interface IP Address

  • Press the F2 key at power on to access the BIOS
  • Under the Server Mgmt tab, open the BMC Network Configuration menu
  • The IP address is listed
  • The management interface can be accessed by using this address in a browser on the same LAN